            水蒸汽检测管6LLP Water vapour,Measuring Range 2 to 10 LB/MMCF Number of Pump Strokes 2 Correction Factor 1 Sampling Time 3 minutes per pump stroke Detecting Limit 2 LB/MMCF (n=2) 
        
    
            详情介绍:
        
        水蒸汽检测管6LLP  Water vapour
Watervapour           No.6LLP
H2O
水蒸汽检测管6LLP Water vapour
| Performance | 
| MeasuringRange | 2 to 10LB/MMCF | 
| Number of PumpStrokes | 2 | 
| CorrectionFactor | 1 | 
| SamplingTime | 3 minutes per pumpstroke | 
| DetectingLimit | 2 LB/MMCF(n=2) | 
| ColorChange | Yellow → Green | 
| ReactionPrinciple | H2O + Mg(ClO4)2 → Mg(ClO4)2  | 
| Coefficient ofVariation | 10% (for 2 to 4LB/MMCF), 5% (for 4 to 10 LB/MMCF) | 
| ShelfLife | 3 Years | 
| Correctionsfor temperature & humidity | Temperature correction is necessary | 
| Store the tubes at cool and darkplace. | |
| Possible coexisting substances and theirinterferences | (NOTE) | 
| Substance | Concentration | Interference | Change color byitself | 
| Hydrogen Chloride,Hydrogen Cyanide, Nitric Acid | - | Plus error | - | 
| Sulfur Dioxide,Nitrogen Dioxide | - | Plus error | - | 
| Alcohols |  50 ppm | No effect | Nodiscoloration | 
| Esters, Aldehydes,Ketones,Nitriles | - | Plus error | - | 
| Triethyleneglycol | - | Noeffect | Nodiscoloration | 
| Othersubstance measurable with this detector tube | 
| Calibration gasgeneration | Diffusion tube method | |
| TLV-TWA | TLV-STEL | Explosive range | 
| - | - | - | 
 
    
 H
H