简单介绍:
四氯化碳检测管134L CCl4,四氯化碳检测管134L CCl4 Carbon tetrachloride,Measuring Range 0.25 to 5 ppm 5 to 12 ppm Number of Pump Strokes 2 1 Correction Factor 1 2.4 Sampling,四氯化碳检测管价格
详情介绍:
四氯化碳检测管134L CCl4 Carbon tetrachloride No.134L
CCl4
Performance |
Measuring Range | 0.25 to 5 ppm | 5 to 12 ppm |
Number of PumpStrokes | 2 | 1 |
CorrectionFactor | 1 | 2.4 |
Sampling Time | 2 minutes per pumpstroke | |
Detecting Limit | 0.05 ppm (n=2) | |
Color Change | White → Yellow | |
Reaction Principle | CCl4 + I2O5 + H2S2O7 → COCl2 | |
Coefficient ofVariation | 10% (for 0.25 to 1 ppm), 5% (for 2 to 5 ppm) | |
ShelfLife | 1Year | |
Correctionsfor temperature & humidity | Unnecessary | |
Store the tubes inthe refrigerator to keep at 10oC (50oF) orbelow. |
Possible coexisting substances and theirinterferences | (NOTE) |
Substance | Concentration | Interference | Change color by itself |
Hydrogen chloride | - | None | Nodiscoloration |
Chlorine, Bromine | 5 ppm | Plus error | Produce yellowstain |
Methyl bromide | 20ppm | Plus error | Yellow |
1,1,1-Trichloroethane | 20 ppm | Plus error | Yellow |
Calibration gasgeneration | Diffusion tubemethod |
TLV-TWA | TLV-STEL | Explosive range |
5ppm | 10ppm | - |