简单介绍:
胺类检测管180 Amines R-NH2,胺类检测管180 Amines,Measuring Range 5 to 100ppm Number of Pump Strokes 1 Correction Factor 1 Sampling Time 1 minute per pump stroke Detecting Limit 0.5 ppm (n=1)胺类检测管价格
详情介绍:
胺类检测管180 Amines R-NH2
Amines No.180
R-NH2

Performance |
MeasuringRange | 5 to 100ppm |
Number of Pump Strokes | 1 |
Correction Factor | 1 |
SamplingTime | 1 minute per pumpstroke |
DetectingLimit | 0.5 ppm (n=1) |
ColorChange | Pink →Yellow to Brown |
ReactionPrinciple | 2R![]() ![]() |
Coefficient ofVariation | 10% (for 5 to 20%), 5% (for 20 to 100 %) |
ShelfLife | 3 Years |
Correctionsfor temperature & humidity | Temperature correction is necessary |
Store the tubes at cool and darkplace. |
Possible coexisting substances and theirinterferences | (NOTE) |
Substance | Concentration | Interference | Change color by itself |
Amines,Ammonia | Plus error | Discolor to yellow | |
Aniline, Hydrazine,Pyridine | Plus error | Yellow to brown discoloration | |
Amidos | No | No discoloration |
Othersubstance measurable with this detector tube |
The Tube 180 can also be used todetect the following substances with correction factors
Substance | PumpStroke | Correction | Detecting Range(ppm) | ColorChange |
Allylamine | 1 | 1.7 | 8.5 to 170 | Yellow |
Ammonia | 1 | 0.3 | 1.5 to 30 | Yellow |
n-Butylamine | 1 | 1.6 | 8 to 160 | Grayish red toBrown |
tert-Butylamine | 1 | 1.1 | 5.5 to 110 | Pale brown |
Di-n-Butylamine | 1 | 1.0 | 5 to 100 | Pale orange |
Cyclohexylamine | 1 | 1.4 | 7 to 140 | Salmon pink |
Diethylamine | 1 | 1.1 | 5.5 to 110 | Pale brown |
Diethylethanolamine | 1 | 1.2 | 6 to 120 | Pale brown |
Diisopropylamine | 1 | 1.0 | 5 to 100 | Pale orange |
Dimethylethanolamine | 1 | 1.3 | 6.5 to 130 | Pale orange toYellow |
Dimethylamine | 1 | 1.1 | 5.5 to 110 | Salmon pink |
Dimethylaminopropylamine | 1 | 1.6 | 8 to 160 | Grayish red |
N,N-Dimethylethylamine | 1 | 0.8 | 4 to 80 | Yellow |
Dipropylamine | 1 | 0.8 | 4 to 80 | Yellow |
N-Ethylmorphorine | 1 | 1.0 | 5 to 100 | Yellow |
Ethylamine | 1 | 1.0 | 5 to 100 | Yellow |
Ethylenediamine | 1 | 2.8 | 14 to 280 | Yellow |
n-Hexylamine | 1 | 1.8 | 9 to 180 | Pale orange |
Isopropylamine | 1 | 1.1 | 5.5 to 110 | Salmon pink |
Methylamine | 1 | 1.0 | 5 to 100 | Pale brown toYellow |
N-Methylmorpholine | 1 | 1.0 | 5 to 100 | Yellow |
N-Methyl pyrrolidone | 1 | 2.7 | 50 to 270 | Yellow |
Monoethanolamine | 3 | 1.4 | 7 to 140 | Yellow |
Morpholine | 1 | 1.8 | 9 to 180 | Yellow |
Propylamine | 1 | 1.2 | 6 to 120 | Salmon pink |
Propyleneimine | 1 | 1.1 | 5.5 to 110 | Yellow |
Tetramethylenediamine | 1 | 1.7 | 8.5 to 170 | Purple toYellow |
Triethylamine | 1 | 0.9 | 4.5 to 90 | Yellow |
Trimethylamine | 1 | 0.7 | 3.5 to 70 | Yellow |
Calibration gasgeneration | Diffusion tubemethod |